TS790+ & TS900+ Installation Manual System Installation
Installing a Monitored Power Supply
The TS790+/TS900+ can be configured to
monitor the 519XB power supply unit using the
519FM fault monitor PCB. The 519FM plugs
directly onto the 519XB PCB plug labelled JP1.
The 519FM PCB monitors any combination of:
Supply Failure (mains)
Low Battery Voltage
12V Failure (fuse failure)
In order to monitor the above fault conditions,
the outputs on the 519FM must be connected
to a detection circuit.
If required, the PSU battery can be “load tested”
periodically by connecting a switched +ve
output to the 519FM BATT TEST terminal. The
battery test occurs every hour on the hour for 30
seconds, if during this time the battery voltage
drops below 11.25V a “Battery Fault” indication
will be generated.
PSU. Power
PSU. Batt
PSU. Fuse
Supply
Fail
Battery
Low
12V
Fail
Batt Test
0V
Aux 0V
O/P
A+
TC
TB
TA
ZC
ZB
ZA
CIRCUIT CCIRCUIT BCIRCUIT A
Battery Test (045)
Program As:-
XNODE
519 FM
Figure 25. 519FM Connections
Pre Power-Up Checks
Once the system is installed, but prior to
powering-up give the system one final check to
ensure that:
1. The wiring conforms to the requirements
detailed in this manual and that all
interconnections are correct (A to A, B to B
etc.).
2. All system cables are kept clear of mains
supply cables, telephone cables and R.F.
cables. It is recommended that cable ties
be used to keep cables separated.
3. Verify that maximum cable lengths and
resistances are not exceeded.
4. Mains power supply cables to the system are
connected to an un-switched fused spur.
5. Grommets are used where cables enter
metal housings to ensure that insulation is
not compromised.
6. At least one keypad is connected.
Initial Power-Up
To power the system for the first time:
1. Place a small screwdriver blade between
the pins on the control panel PCB, marked
“FACTORY RESET”. This will ensure the factory
default parameters are set, see page 22.
2. Switch on the 240V mains supply. Leave the
screwdriver blade between the pins for at
least 10 seconds before removing the
screwdriver.
3. Check that the power LED on the control
panel PCB is illuminated.
4. Check that the LED remote keypads display
LT” (Panel Lid tamper) and LCD remote
keypads display “Panel Lid tamper”. The
remote keypad sounders and extension
loudspeakers will operate.
If the keypad display shows the words
“Foreign Letter” then ensure that the
keypad is correctly connected, remove
all power, and repeat steps 1-4.
5. Enter the engineers passcode (default 1234)
to silence the sounders.
6. Connect the standby battery.