TS790+ & TS900+ Installation Manual System Installation
as normal. When the link is set to the
enabled position the sounder is only
enabled when the remote keypad
programmable output is active. For
example, to make the keypad ward
respective for ward A, program the output
on the remote keypad to "Sounder Control
A" (type 064) and set the "Ward Sounder
Control" link to the enabled position. (Hint:
use Engineer Menu 1 option 1. Panel o/p 5
= keypad o/p 1, panel o/p = keypad o/p 2
and so on.)
7. Finally clip the remote keypad cover onto
the base being careful not to trap any
cables or to obstruct the tamper switch.
Engineer’s Keypad
Normally all system programming will be carried
out from one of the installed remote keypads,
however sometimes it may be more convenient
to program the system at the control panel. This
can be achieved by using an “Engineers
Keypad” which is temporarily plugged on to the
control panel (JP2).
DO NOT plug the Engineer’s Keypad into JP1
or you may damage the equipment.
To convert a standard remote keypad to an
“Engineers Keypad” an Engineer’s interface lead
is required which can be obtained from your
supplier (P/No. NETEKI).
Figure 10. Engineer’s Keypad Connections
XNode (TS900+)
The XNode is very similar to the TS900 Node in
that it provides the facility to add an extra eight
programmable detection circuits and two
programmable outputs. The maximum number
of XNodes that can be connected to any one
network is 5.
XNode Wiring
The XNode requires a 4 core cable for
interconnection, and up to 5 may be
connected in a “daisy-chain” or “star
configuration. The distance between each
XNode must not exceed 100 metres. The total
distance to last XNode must not exceed 500
metres. The Aux. +/- terminals provide power for
the detectors.
Programmable Outputs on the XNode
The XNode has two programmable outputs,
each rated at 100mA, output [A+] is a switched
+ve output and output [B-] is a switched -ve.
The outputs can be used to drive sounders or
relays etc.