TS790 & TS90010 - 56 Zone Intruder AlarmControl PanelsInstallation & ProgrammingManual123456789ENT0ESCA BCOMIT AREAPOWERBUSY123456789ENT0ESCA
Control Panel PCB LayoutOUTPUT MODULE PRINTER1 AMPNODE SUPPLYREMOTEKEYPADJP3DIGI-MODEMFACTORYRESETNode Networkconnection terminals(TS900 Only)Auxiliar
Connection Terminals & IndicatorsThe main PCB has the following “Jumper Plugs” (JP)and indicator LEDS:JP1 PRINTERThis 6-pin plug is used for conne
Mains ConnectionThe mains supply is connected to a 3 way "EuroType" fused terminal block, which is fitted with a315mA fuse. All electrical c
TS700 LED Remote KeypadThe TS700 remote keypad has a 4 character LEDdisplay.TS700 Remote Arming StationThe TS700 remote arming station only has twoind
position the sounder responds as normal.When the link is set to the enabled position thesounder is only enabled when the remotekeypad programmable
TS900 Node LayoutA B F G A B F GAUX 12VAUX 12V500mANODE I/DJP2ZAZHZGZFZEZCZDZBCIRCUIT ACIRCUIT HCIRCUIT GCIRCUIT FCIRCUIT ECIRCUIT CCIRCUIT DCIRCUIT B
TS700 LEC InstallationThe TS700 LEC (Local Expansion Card) isconnected to the “Remote Network” and providestwo additional programmable detection circu
End Of LineThe EOL method requires the following:The detector alarm contacts must have a 4K7shunt resistor fitted.A 2K2 End of Line (EOL) resistor mus
Installing an External Sounder from a NodeThe TS900 Node has two programmable outputs,these can be utilised to drive an external sounder.However, it i
Digicom/RedCARE InstallationAstandalonedigitalcommunicator,RedCARESTUor Paknet interface card can be connectedto thecontrol panel using the following
Output Modules Installation (CPA6.OM)Output Modules (CPA6.OM) can be used toprovideasetof outputstoLEDsorrelaystoindicateeither circuit alarm activati
Programmable OutputsThe TS790/900 has many programmable outputswhich can be used to drive relays, LED’s etc. Eachoutput can be programmed for a differ
Installing a Monitored Power SupplyThe TS790/TS900 can be configured to monitor the519XB power supply unit using the 519FM faultmonitor PCB. The 519FM
Power-Up ChecksWhen the initial power-up checks have beencompleted, check the following:1. Switch off the 240V mainssupply and measurethe DC voltag
Section Option DefaultCircuitsCircuit 07 Exit TerminatorCircuit 08 PA AudibleCircuit 09 Final ExitCircuit 10 PA AudibleCircuit 11 - 56 Not UsedSystem
Engineer’s Menu 1IntroductionEngineers menu 1 is the first of three engineersmenus, which is selected when the engineer’spasscode is entered. The engi
Panel OutputsOutputs 1 - 4 on the the control panel and remotekeypad outputs 5 - 8 can be programmed to anyof the output types shown on page 22 .Digic
No/Type Description006P.A.Activates when a PA alarm is detectedand deactivates when the alarm isreset.007FireActivateswhenaFirealarmisdetectedand
No/Type Description040Time Switch AThisoutputiscontrolledbythe settings of“Time Switch A” (seeEngineers Menu 3)041Time Switch BThisoutputiscontrolledb
Program CircuitsThe TS790 can monitor up to 16 detection circuits,whereas theTS900can monitor upto 56detectioncircuits.Eachcircuitmustbeprogrammedinor
ContentsOverviewIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . 1System Architecture . . . . . . . . . . . . . . . . . . . 1Control Pan
Circuit AttributesEach circuit type can have one or more attributesassigned to it to alter its operation. The followingcircuit attributes can be progr
System TimersThe system timers are as follows:00 ACPO DelayFor ACPO requirements this timer normally setto 90 seconds. If during the entry procedureth
07 Bell DelayThis timer delays the activation of the externalbell/sounder and internal sounders. This timerhas aworkingrange of000-199 minutes.Note:An
18 Ward Menu DurationIf the timer is set to 000 the “Code Set Group”passcodes function as normal, i.e., when theuser enters their passcode the exit ti
Setting ModesThe setting mode for full set and each part set canbe configured to the following setting modes:1 Final ExitThe system will set when the
Remote Reset AlgorithmWhen the system is programmed for “EngineerReset” the requirement to send an engineer to sitecan be overridden by the user by us
10 O/M's Mimic CircuitsWhen programmed as “Yes" the outputmodules mimic circuit activations. Whenprogrammed as ”No" output modules giv
Goto User Menu 1This option allows the engineer to access “Usermenu 1", the flowchart below shows the optionswithin ”User menu 1", for full
View Location Text (LCD Only)This option allows the engineer to view the panellocation text. The text message is programmed in"Engineers menu 3&q
Engineer's Menu 2IntroductionEngineer's menu 2 is selected by pressing the [ENT]key whilst Engineer's menu 1 is selected. Eachmenu opti
Set System Date. . . . . . . . . . . . . . . . . . . . . . 36Change Passcode . . . . . . . . . . . . . . . . . . . 36Chime Circuits. . . . . . . . . .
View CircuitsEachdetectioncircuitmaybeviewedtoascertainits status. The circuit status conditions andresistance are shown below:Status Response Normal
Chime CircuitsThis option allows an alternative method ofprogramming circuits as “chime”.Alter 24Hr GroupCircuit types “24hr” and “Auxiliary” with the
Log Event CodesView System LogTheengineercanusethisoptiontoviewthesystemlog. The [A] and [C] keys allow you to scrollbackwards and forwards through th
Log Event CodesLCD Starburst LED DescriptionDATE CHANGEDDATE CHGDcSystem Date changed.DEFAULT CODEDEFLT 01DFUser passcode (01) reset to 5678 by the en
Log Event CodesReset User Code 1This option allows the installation engineer to resetthe master user (user 01) back to the factorydefault code of
Engineers Menu 3IntroductionEngineers menu 3 is selected by pressing the [ENT]whilst Engineers menu 2 is selected. Each menuoption can be selected by
Time SwitchesThe TS790/TS900 has three programmable timeswitches. Each time switch can be programmedwith up to three separate on/off times and madeto
Part Set GroupsThis option allows the engineer to define how thethreepart setbuttonsoperate.Each groupcanbeprogrammed so that it sets any combination
Engineers Name (LCD Only)This option allows the engineer to assign a name(7 characters) to user 00. When using the view logoption you can press the
Location TextThis option allows the engineer to program a 32character location message. When “Engineersmenu 1" is selected the engineer can vie
OverviewIntroductionThe TS790 and TS900 alarm control systems havebeen designed to suit medium to large installationsites. The TS900 system can be exp
VoltageWhen this test option is selected the batterycharging voltage atthe controlpanelisdisplayed,the accuracy of this measurement is ± 0.2V.View Cir
Custom Outputs A & BTheseoptionsallowstheengineertoprogrambothcustom outputs. The diagram below represent thelogic circuit for the the custom outp
Modem Options (LCD Only)This option allows the engineer to access thefollowing modem options:Call Back No.1This option allows the first call back
Digi programmingPress ESC to end6ENTENTENTENTENTENTENTENTENTENTENTENTModem optionsSelect Option :-Engineers menu 3Select Option :-CTELEPHONE NO. 1ACCO
Reset DigicomWhen the system is powered up, the control panellogs-on the device that is connected to thedigicom plug (JP3). If the device is changed o
AppendicesPoint ID Extended ReportingPoint ID extended reporting is a new format whichwhen used with the DC58 or DC58M can be usedtoreportcircuitIDdat
PPPPPRKCCCCCCSSCPCPRKKey:10987621354Bedroom 1Bedroom 2BathroomLandingBedroom 3LoungeGarageKitchenDining RoomHallPassive Infra-Red DetectorMagnetic Con
Domestic Part-Set Application ExampleThe TS790/900 is very flexible in the way that thesystem can be part-set. The system may bepart-set by using the
Defining Part-Set buttons to Arm a Ward(s)Thismethodofdefiningthepartsetgroupsrequiresyou to think of the system in terms of separateareas of protecti
PPPPPPPPPPCCCCCCCCCCRKCPRKRKRKRKCPKey:12 143576891011121315164Workshop CanteenStoresSalesOfficeService DepartmentPassive Infra-Red DetectorMagnetic Co
Remote KeypadsUp to 4 remote keypads can be connected tothecontrol panel. Each remote keypad has twodetection circuits and a single switched -veoutput
Commercial Part-Set ApplicationThis application example shows how to use the"Code Set Groups" to set and unset different areaswithin a comme
1. Program the Detection Circuit as a “Key Point”and set the attributes as “F * * * |* A * *”. The“F” attribute indicates that the “Full Set Group”iss
1. Ifaplug-ondigicomisbeingusedprogramthedigicom channels as shown below, see“Plug-on Digi Channels”, on page 22. If astand-alone digicom is being u
Setup New UsersThe TS790/TS900 allows up to 31 users to operatethe alarm system, each user is assigned a usertype, passcode and ward access. User 001
Code Set Group BUsers 02-31 can be programmed as "Code SetGroup B". This user type only allows the wardsassigned by the installation company
NotesTS790 & TS900 Installation Manual Appendices61
Engineers MenusUser MenusEngineer's Menu 1 Engineer's Menu 2 Engineer's Menu 31Panel Outputs1View Circuits1Time Switches2Digicom Output
No. Output Type000 Bell On001 Strobe On002 Switch 12V003 Detector Reset004 Walk Test005 Alarm006 P.A.007 Fire008 System Set009 Code Accepted010 24 Hou
18796 Drg No. 33:1429:00 Issue 04 Doc. 01MENVIERSECURITYMenvier Security Ltd.Kenn Road, Clevedon, Bristol BS21 6LHTel: 01275 870078; Fax: 01275 343453
System InstallationCable RoutingWhen installing cables, the following should benoted:+Screened cable may prove necessary iftheNetwork is run adjacent
Remote Network WiringDevices on the “Remote Network” require a 6 corecable for interconnection, and may beconnected in a “star” or “daisy-chain”config
Control Panel InstallationProceed as follows:1. Open the control panel by removing twoscrews from the front cover. Removethecoverby slidingitup slig