Part Set Groups
This option allows the engineer to define how the
three part set buttons operate. Each group can be
programmed so that it sets any combination of
wards. For example "PART SET GROUP A" could be
allocated wards A and C, whereas "PART SET
GROUP B" could be allocated wards A and B.
Each “Part Set Group” can also have up to 32
characters of text assigned, see "Edit Text For Part
Set Groups" on page 44.
Part Set Group Operation
When a “Master” or “Standard” user passcode is
entered during the unset mode the system will
attempt to fully set after a five second delay.
However, if during the five second delay one of the
part set buttons [A], [B] or [C] is pressed, the display
will show relevant “Part Set Text” and after a short
delay the system will set the wards that are
assigned to the selected “Part Set Group”.
Code Set Groups
This option allows the engineer to define how the
four code set groups operate. Each group can be
programmed so that it sets any combination of
wards. For example "CODE SET GROUP A" could be
allocated wards A and C, whereas "CODE SET
GROUP B" could be allocated wards A and B.
Code Set Group Operation
When the system is unset and a “Code Set Group”
passcode is entered the selected wards will set
after the setting procedure is followed. e.g., If
“Code Set Group A” is defined as above then
when the passcode is entered it will set wards A
and C. If the system is fully set and the passcode is
entered it will unset wards A and C.
The “Code set Group” passcodes are
programmed by the master user within “User
menu 2" (see User Manual).
43
TS790 & TS900 Installation Manual Engineers Menu 3
Code set Group ?
Enter Group > -
Code set Group B
will set [ B ]
Code set Group B
will set [ AB ]
Enter group:
= Code Set Group A
= Code Set Group B
= Code Set Group C
Wards
3
A
B
C
e.g. B for code set group B
Select wards:
= Ward S (System)
=WardA
=WardB
0
A
B
=WardC
C
ENT
e.g. A
= Full Set Group
0
Engineers menu 3
Select Option :-
StarburstLCD
LED
E3 -
ENGR 3 -
CSG.-
C.S GRP-
B
B
AB
AB
Code Set Groups Flowchart
Part set Group ?
Enter Group > -
Part set Group A
will set [ A ]
Part set Group A
will set [S B ]
Enter group:
= Part Set Group A
= Part Set Group B
= Part Set Group C
Wards
2
A
B
C
e.g. A for part set group A
Select wards:
= Ward S (System)
=WardA
=WardB
0
A
B
=WardC
C
ENT
e.g. 0AB
Engineers menu 3
Select Option :-
StarburstLCD
LED
E3 -
ENGR 3 -
PSG.-
P.S GRP-
A
A
SB
SB
Part Set Groups Flowchart
Zobrazit stránku 46