Remote Reset Algorithm
When the system is programmed for “Engineer
Reset” the requirement to send an engineer to site
can be overridden by the user by using the
“Remote Reset” facility. If an alarm is generated
the system will respond with a four digit “seed”
code which the user quotes to the Alarm
Receiving Centre or alarm company. The “seed”
code is then entered into a decoder and a unique
“Remote Reset” code is generated. This is passed
back to the user and on entering the “Remote
Reset” code, the system is reset.
The “Remote Reset” code is generated using an
algorithm identified by a 3 digit number.
Alternative algorithms can be selected but these
must correspond to that used by the ARC (or alarm
company) otherwise the “Remote Reset” code will
be incorrect. (Default = 004)
Configuration
The configuration options are as follows:
00 Bell Is an SAB
When programmed as “Yes” the control panel
bell output applies 0V when active. When
programmed as “No” the control panel bell
output removes 0V when active. (Default =
Yes)
01 User 1 Limited
When programmed as “Yes” user 1 is disabled
from options 6 and 8 in user menu 2 , and all
options in user menu 3. When programmed as
“No” user 1 has access to all user menus and
options. (Default = No)
02 Fire Signals all
When programmed as “Yes” fire alarm
activations are signalled to the ARC at all
times. When programmed as “No” fire alarm
activations are signalled to the ARC only when
the system is full set. (Default = Yes)
03 Silent 24hr Circuits
When programmed as “Yes” 24hr circuit are
silent. When programmed as “No” 24hr circuits
are audible. (Default = No)
04 Enable Duress
When programmed as “Yes” the reversal of the
first two digits on any passcode will generate a
duress alarm. When programmed as “No” the
reversal of the first two digits on any passcode
will NOT generate a duress alarm. (Default =
No)
05 PA Silent
When programmed as “Yes” PA’s activated by
pressing keys 1& 3 on the remote keypad will
be silent. When programmed as “No” PA’s
activated by pressing keys!&3ontheremote
keypad will be audible. (Default = Yes)
06 Set with Line Fault
When programmed as “Yes” the system can
be set with a telephone line fault, however the
user will be asked to confirm this at the time of
setting. When programmed as “No” the system
cannot be set with a telephone line fault.
(Default = Yes)
07 User Reset
When programmed as “Yes" alarms can be
reset by the user. When programmed as ”No"
alarms can only be reset by the engineer or via
remote reset. (Default = Yes)
08 Tamper Engineer Reset
When programmed as “No" the user can reset
daytime tamper alarms. When programmed
as ”Yes" only the engineer can reset daytime
tamper alarms. (Default = Yes)
09 High Security Engineer
When programmed as “Yes" the engineer
must enter his passcode and remote reset
number to gain access to engineer's menu 1.
When programmed as ”No" only the
engineer's passcode is required to access
engineer's menu 1. (Default = No)
31
TS790 & TS900 Installation Manual Engineer’s Menu 1
Remote Reset
Algorithm > 004
Remote Reset
Algorithm > 010
Engineers menu 1
Select Option :-
Algorithm No.
8
Enter new No.
e.g. 010
ENT
StarburstLCD
LED
E1 -
ENGR 1 -
004
004
010
010
Remote Reset Algorithm Flowchart