Mains Connection
The mains supply is connected to a 3 way "Euro
Type" fused terminal block, which is fitted with a
315mA fuse. All electrical connections should be
carried out by a qualified electrician and must
comply with the current IEE regulations.
To comply with european regulations the
supply should be fed from a readily
accessible disconnect device, e.g.
un-switched fused spur fitted.
When making mains connections it should
be ensured that if the cable slips in such a
way as to place a strain on the conductors,
the protective earthing conductor will be
the last to take the strain.
Battery Connection
A 7Ah battery must be fitted to the system to allow
it to function during a mains fail condition. The
TS790/TS900 is equipped with a “Battery Protection”
circuit so that if a battery is accidentally reverse
connected or its voltage is below 4V, the “Battery
Fault” LED illuminates. To clear the fault simply
reconnect or replace the battery as appropriate.
Remote Keypads
Four types of remote keypads can be used on the
system, however, only the TS900 remote keypad
can be used for programming text information.
Any combination of remote keypad may be used
on the same system if desired.
NETLCD Remote Keypad
The NETLCD remote keypad has a 32 character
backlit Liquid Crystal Display (LCD)
NETSTAR Remote Keypad
The NETSTAR remote keypad has a 8 character
backlit Starburst Liquid Crystal Display (LCD).
NETLED Remote Keypad
The NETLED remote keypad has a 4 character LED
display.
NETARM Remote Arming Station
The NETARM remote arming station does not have
a display, therefore it is designed to only be used
where setting, part setting and unsetting of the
system is required.
PCB Layouts & Connections
Detection Circuits.
Each remote keypad has two
programmable detection circuits.
Loudspeaker Volume.
For adjusting the volume of a speaker wired
to the remote keypad (NETLCD only).
LED Mimic.
If this jumper link is set to the “enabled”
position, the red () LED on the keypad will
be “ON” when the keypad output is active.
Remote I/D.
Used to select the remote keypads address.
(ENG = Engineer).
Ward Sounder Control.
If this jumper link is set to the “disabled”
position, the remote keypad sounder will
follow the control panel speaker output. If
this link is set to “enabled”, the remote
keypad sounder will only activate when the
panel speaker and the output on the
remote keypad are active at the same time.
Loudspeaker Output.
This terminal can be connected to a single
16 Loudspeaker (NETLCD only).
Network Connections & O/P.
Terminals A to E are used to connect the
remote keypad to the control panel
network. The O/P terminal is the
programmable output.
8
System Installation TS790 & TS900 Installation Manual
L
E
N
To transformer
FUSE 315mA
Figure 7. Mains Supply Connections