TECHNICAL BULLETIN
TSD402/001
TSD402 CONTROL PANEL
Our Technical Support Department have received one instance regarding the facility to
record messages on the above product.
It is possible that if the microphone is pushed firmly onto the PCB, the housing can touch on
one of the PCB tracks, the resulting short thereby causing a problem which can be identified
by a background “humming” sound when recording messages.
If you have a PCB exhibiting this symptom, try gently pulling the microphone away from the
PCB, a piece of paper can act as a suitable insulator (see diagram below for location of
microphone). If this fails to cure the problem, please return the PCB to Menvier at the
address shown below.