TECHNICAL BULLETIN
NACOSS CODES OF PRACTICE NACP14
The following is intended to inform the you about the requirements of NACP14 and its affect on
you and the compatibility of MENVIER's range of control panels and accessories.
The following paragraph is taken from NACP 14
2.1.1 Facilities To Aid Filtering-Out Of False Calls
All alarm systems within the scope of practice shall either:
(a) have means to indicate to the alarm receiving centre whether the alarm
system is set or unset;
OR
(b) be capable of generating a secondary signal to indicate to the alarm receiving
centre that the alarm system has been mis-operated.
In the case of alarm systems coming into operation on or before 31 December
1995 implementation of the above is deferred until 31 December 1996.
2.1.2 Means Of Completion Of Setting.
For all new alarm systems within the scope of this code of practice , coming into
operation on or after 1 January 1996 the completion of the full setting procedure
shall be achieved by means which involve positive action on the part of the
keyholder.
Translating the above into English, you will have to do the following on all
new systems
and
upgrade
existing systems
by 31 December 1996:
1. Send an open / close signal to the central station
OR
Send the Central station an Abort Signal.
2. Fit exit terminator buttons or final exit shunt locks to all
new installations
.
NOTE. Any system fitted with a REDCARE
must
send open / close signal as the central
monitoring station will not police a no-response during the open state.
What must be appreciated is with the number of installations going in, the number of calls that
the central station are going to be processing will go through the roof. The answer would be to
only send the signal when needed which would be the ABORT signal. But you say how can my
existing jobs signal abort when the panel does not have the facility. The answer is to fit a
Menvier Abort Module which would be able to interface to your older / other control panels and
create an abort output for you.