User Me nus
11. Introduction
In addition to setting and unsetting the system, users 1 - 9 may
carry out other operations. These are selected via two user
menus,"Us erMenu 1" isavail able to users1 - 9and "UserMenu 2"
which is only available to the master user. T o access "User Menu
1" enter your passcode and then press [ wit hin 5 seconds.
Pressing ] returnstheusert o thepreviouspositioninthemenu.
12. Bell test
This test allows the user to test the bells, sounders and strobes.
1. Ensure that "User Menu 1" is selected.
2. Press 1 to select the Bell Test option.
3. The sounde rs, bells and strobes will operate sequentially for
9 sec onds each.
4. Te sting maybe stoppedbypressing ] oradvancedtonext
test by pressing [.
13. Walk Test
This test allows the user to test the function of individual circuits
without creating an alarm.Aseachcircuitis activateditsnumber
and status are disp layed and the internal sounder generates a
two-tone sound. As more circuits are tested t hey are added in
turn to a scrollin g display showing the status of each tested
circuit.
1. Ensure that "User Menu 1" is selected.
2. Press 2 to select the Walk Test option.
3. Activate circuits in turn by opening doors with contacts and
walking in front of detectors.
4. Checkthedisplayto verifywhich circuitshavebeentested.
5. On completio n p ress ] to quit the Walk Test option.
6
TS700 LED User Operating Instructions
ON 9
Co unt down display for Bell Test.
1 -
Tes t completed. "User Menu 1"
selected .
NONE
Walk Test selected, but no
circuits have been tested.
05-A
Circuit 05 is now active
05-H
Circuit 05 is now healthy