Print System Log
A printer may be connected to produce a print-out of the last 200 system e vents.
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 7 to select the Print Log option.
3. Enter the nu mber of events to be printed.
4. Press [ to s tart printing. To stop printing select the menu again
and enter 000 as the number of events to be printed .
Conf igure Part-Set Groups
When the system is part-set certain circuits are omitted. This option allows the engineer to select
those ci rcuits to be omitted when part-set A or B or C is selected.
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 8 to select the Part-Set Grou ps op tion.
3. Select the part-set group A or B or C.
4. Circuits will be displayed as O(Omitted) or A(Armed). Press 0 to
change ("toggle" action).
5. Press [ to accept displayed status (high tone) and go to next
circuit. Circuits may be selected by number.
6. Press ] to return to step 3 and ] again to return to "Engineer
Menu 2".
View System Log
The time, date and nature of the last 200 events on the system may be viewed starti ng with the
most recent event.
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 9 to select the View Log option.
3. The most recent event will be displayed (see Table 7)
4. PressA to scrollbackandC t o scrollforward.PressB to showthe
time of the event (first press), the date (second press) the time in
minutes and seconds (third press).
5. Press ] to abandon.
Reset Master User 1
Thisoption allows theengineerto reset themasteruserpasscodebacktothefa ctory defaultcode
`5678' . Thisfeature isusefulwhen themasteruserhasforgottentheirpasscodeorhasi nadvertently
changed it.
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 0 to Reset U ser 1.
24
Programming TS700 Installation Manual
CA.01
Log event showing `Circuit
Alarm 01'. Press A to scroll back
or C to scroll forward. Press B to
view time and date.
01-A
Circuit 01 wi ll remain Armed.
Press 0 to change.
01-O
Circuit 01 wi ll b e Omitted.
Press ENT to accept.
PS -
Ent er part-set group A, B or C.
---
Ent er the number of events to
be printed. Press ENT to start.